TBA Penowrap System

TBA Firefly Penowrap® is used in conjunction with other TBA Firefly products to maintain the FRL of various walls, floors and ceilings where they are penetrated by either structural or service penetrations.

Tested in accordance with AS1530.4-2014 and Assessed in accordance with AS4072.1-2005.

  • Steel Universal Beams
  • Timber Beams
  • C & Z Steel Purlins
  • All sizes and bundles of Power Cables used in Australia (with or without Steel Cable Trays)
  • All sizes and bundles of Comms Cables used in Australia (with or without steel Cable Trays)
  • Full range of VASS Electrical Busducts with either copper or aluminium conductors
  • Full range of EAE Electrical Busducts with either copper or aluminium conductors
  • Full range of ABB Electrical Busducts with either copper or aluminium conductors

The referenced compliance reports below are from an accreddited testing laboratory which meet Specification A2.3 of NCC2016 amendment 1 (including prior versions) & Schedule 5 of NCC2019 (Including Ammendment 1) for determination of an FRL. 

  • Warringtonfire
    • FAS190234 RIR
    • FAS190235 RIR
    • FAS190236 RIR
  • CSIRO
    • FCO-3228 SFA

Please ask for the relevant Regulatory Information Reports from an Accredited Testing Laboratory to ensure that you are covered for your specific Wall, Floor or Ceiling Type and your specific penetration size and orientation.

TBA Firefly Penowrap® is to be installed in Strict Accordance with the concise construction details contained within these Reports.

Promat Bulkhead System

PROMASEAL® Bulkhead Sealer System is made using high density mineral wool that is coated with PROMASEAL® Bulkhead Sealer. The coated mineral wool remains in-situ during a fire situation and forms a barrier against the passage of flame, smoke and toxic gases.

The system is the simplest of all fire stopping products to install. It is also one of, if not the most economical product to use. It can be installed in both concrete/masonry floors and walls (with an equal or greater fire resistance level) and has been tested up to 120 minutes with various penetrating applications.

In many buildings, power cables (e.g. information technology and telecommunication services) are continuously added, altered and removed. PROMASEAL® Bulkhead Sealer System enables this process to be carried out with the minimum of mess and inconvenience.

PROMASEAL® Bulkhead Sealer Systems are non loadbearing.

Promat Fire Collar System

PROMASEAL® Bulkhead Sealer System is made using high density mineral wool that is coated with PROMASEAL® Bulkhead Sealer. The coated mineral wool remains in-situ during a fire situation and forms a barrier against the passage of flame, smoke and toxic gases.

The system is the simplest of all fire stopping products to install. It is also one of, if not the most economical product to use. It can be installed in both concrete/masonry floors and walls (with an equal or greater fire resistance level) and has been tested up to 120 minutes with various penetrating applications.

In many buildings, power cables (e.g. information technology and telecommunication services) are continuously added, altered and removed. PROMASEAL® Bulkhead Sealer System enables this process to be carried out with the minimum of mess and inconvenience.

PROMASEAL® Bulkhead Sealer Systems are non loadbearing.

Promat SupaWrap

Foil Faced Rockwool Sleeve or Blanket

PROMASEAL® SupaWrap is designed to provide insulation criteria onto metal pipes, cables and cable trays.

The deemed to satisfy requirements of the Building Code of Australia requires copper pipes and other service penetrations to be able to achieve the same insulation criteria as the element they are passing through when tested to the requirements of AS 1530.4:2014.

For metal pipes in walls and all services through slabs. A length of 600mm is required using the PROMASEAL® SupaWrap. Generally, the requirement is for application to both faces of the element. However, for slabs there are selected approvals available for application to the top side only.

Cable trays and cables while not as highly conductive as metal pipes will still transfer heat to the unexposed side of a fire resisting element. In these cases the penetrating element must be protected so as to not transfer this heat and possibly contribute to fire spread. The advantage of the PROMASEAL® SupaWrap product is that the extension of the wrap is only for 300mm* (depending on wall thickness) from the face of the wall as opposed to other solutions that can be as long as 800mm.

Trafalgar FyreChoke Conduit Fire Collar

Trafalgar Fire FyreCHOKE Conduit Collars are designed to provide maximum protection against the spread of fire through walls and floors that are penetrated by plastic conduits, plastic pipes. FyreCHOKE Collars are simple to install, simply retro-fit around the service and fix to the wall or floor.

NCC 2022 ready!

Key Features

  • Intumescent fire stopping specifically for plastic pipes and conduit penetrations.
  • Actively expands during fire conditions, forms a tight seal and prevents the spread of fire through the service penetration.
  • Fire tested in a range of wall and floor systems including a wide variety of service types.
  • Stainless steel construction
  • Simple design allows for quick and easy installation of the collars.
  • Sizes 25-40mm

Applications

Suitable for all types of rigid plastic conduits including:

  • Data NBN Conduits
  • Electrical Conduits
  • PVC pipes
  • PEX pipes
  • PEX-AL-PEX pipes

Fire Rating

Up to -/240/240

Trafalgar FyreWrap Pipe Protection Systems

AS 2419.1-2017 requires that where fire hydrant system pipework is likely to be exposed to fire in a building that is not sprinkler protected, the pipe supports shall have measures taken to prevent its early collapse when exposed to fire (per section 10.4.1). To meet this requirement, Trafalgar Fire has engaged expert fire safety engineers to assess the performance of the FyreWrap® Systems.

Fire Rating: 

Up to 90-minute operational protection 

Key Features:

  • Flexible material for easy installation
  • Secured simply with steel cable ties
  • Greenguard listed for microbial resistance
  • Compliant to AS2419 for steel pipe hanger and support protection
  • Compliant to AS2419 for copper hydrant protection

Trafalgar Fyrewrap System

FyreWrap® is the leading passive fire protection solution for commercial ductwork. The lightweight Insulfrax core ensures high temperature insulation and performance. Fibreglass reinforced scrim completely encapsulates the core for additional handling strength, tear resistance and antibacterial resistance.

Key Features:

  • Lightweight – up to 5 times lighter than traditional fire spray
  • Clean and easy installation – no mesh required
  • Greenguard listed for microbial resistance
  • No masking required
  • Quick and efficient construction
  • Simple repair – tape up or replace section
  • Seismic and vibration tolerant
  • Tested and approved in accordance with AS 1530.4-2005 and AS/NZS 1530.4-2014

Promat Spray

PROMASPRAY® P300 is a spray or trowel applied, single package factory controlled premix, based on vermiculite and gypsum.

PROMASPRAY® P300 is a lightweight coating that provides very efficient fire resistance with minimal thickness to return air plenums and air handling ductwork.

Building types that benefit from the use of PROMASPRAY® P300 include a wide range of educational, leisure and entertainment centres, and commercial projects.

Trafalgar Fyreflex Sealant

FyreFLEX® Fire Rated Sealant is a water based, low VOC and environmentally friendly fire rated, intumescent based sealant.  FyreFLEX® has two distinct applications, the first being fire protection of construction and expansion joints in fire rated barriers.  The second application being fire stopping of services passing through openings in fire barriers.

Trafalgar Fyreflex Fyrewrap

TWRAP is a 25mm thick foil-faced, fire protection wrap that has been engineered to provide insulation performance on service penetrations as required by the National Construction Code (NCC) and tested in accordance with AS1530.4-2014.

 

What is TWRAP?

  • 25mm thick foil-faced, fire protection wrap
  • Used with penetration sealing systems
  • Aluminium foil, fiberglass-reinforced outside layer completely encapsulates the core
  • Strong- additional handling strength and tear resistance
  • Resists mould growth
  • Thoroughly tested to AS1530.4-2014

 

Key Features

  • Simple fixing requirements
  • Up to 3 hours fire insulation performance
  • Suitable for cables, cable trays, copper and metal pipes
  • Fully encapsulated wrap system
  • Bio-soluble fibres
  • Easily identified on site for certification
  • Easy to wrap around smaller services
  • Allows for adds moves and changes during the life of the building with a range of Trafalgar
  • Fire’s penetration systems

Promat Structural Timber Column Cladding

When exposed to fire, most softwoods char at about 0.66mm/min and most hardwoods about 0.5mm/min. The fire performance of a timber structural element will obviously depend on these charring rates and the loadbearing capacity of the residual timber.

If the calculated residual timber is inadequate, Promat can offer various solutions normally using a board encasement. Promat also has systems for the protection of timber rafters or bearers where they pass through a fire rated wall. These can be protected either with spray or board systems. Contact Promat technical department for more details.

Promat Fire Protection of Ductworks

The relative complexity of any ductwork system passing through different fire compartments and the relevance of the system’s function in ambient as well as fire conditions can make the selection of a suitable ductwork system difficult.

Promat provides guidance on fire performance requirements and a wide range of solutions for protecting ductwork and other self supporting systems.